TEMPERATURE MEASUREMENT |
|
Scale
Range: |
-30°C to
1100°C or -22°F to 2000°F |
|
Resolution: |
1.0°C or 1.0°F |
|
Accuracy: |
±0.5% Full
Scale |
|
Repeatability: |
±1.0°C or
±2.0°F |
|
Temperature: |
All
Functions in
°C or
°F,
Corresponding to Voltage Out |
|
Noise
Effective Temperature: |
±0.1°C
or ±1.0°F |
|
OPTICAL CONSIDERATIONS |
|
Optical
Configuration: |
Robust,
Aerospace-Quality, Double-Coated Zinc Selenide Optics per Military
Specification MIL-C-13508 |
|
Spectral
Pass Band: |
8 <
Wavelengths < 14 Microns |
|
Sighting: |
Line of
Sight |
|
Field of
View: |
Standard: 2° or
15°
Optional: 60° |
|
OPERATING CONDITIONS |
|
|
Operating
Environment: |
-10°C to
50°C or 14°F
to 122°F, up to 99% Relative Humidity,
Non-Condensing |
|
Storage
Temperature: |
Same as
Operating Environment Temperature |
|
INPUTS/OUTPUTS |
|
Power
Requirements: |
Nickel
Cadmium Rechargeable Batteries |
|
Output
Signal: |
Standard:
RS-232C
Optional: Analog Millivolt (1.0mV/°C) |
|
GENERAL |
|
|
Response
Time: |
0.10 Second |
|
Emissivity
Compensation: |
Settable from 0.2
to 0.98 or Preset at End-User's Request |
|
Operating Distance: |
2 cm to 300 meters |
|
Warranty: |
One Year Limited
Warranty on Parts & Labor |